MXS 25

Professional workshop charging and power supply

MXS 25

Professional workshop charging and power supply

MXS 25

Professional workshop charging and power supply
Image missing

Product information

  • Product information

    Professional workshop charging and power supply

    Temperature regulated charging

    The MXS 25 offers quick, efficient charging and power supply for cars, workshops, RVs, caravans or boats.

    The MXS 25 fully automatic 8 step charger delivers 25A to 12V batteries from 40-500Ah and is IP44 classified for outdoor use. It features automatic battery diagnosis to establish whether your battery can receive and retain a charge, a Recond mode for restoring and reconditioning stratified and deeply discharged batteries, and a temperature sensor for optimised charging regardless of weather conditions. It also has a ‘Supply’ mode so it can be used as a 12V power supply up to 25A.

      ;*;Charges batteries from 40-500Ah ;*;Recond program ;*;Power supply for 12V equipment ;*;Temperature sensor to compensate for cold conditions ;*;IP44 classified for outdoor use
        ;*;Fully automatic ‘connect and forget’ 8 step charging ;*;Patented maintenance charge for longer life batteries ;*;Easy to read LED display ;*;Safe spark free operation ;*;Reverse polarity protected ;*;Short circuit proof ;*;2-year warranty
        Technical information
        Input
        220–240VAC, 50–60Hz, 2.9A max
        Output
        14.4V/15.8V/13.6V, 25A max
        Start voltage
        2.0V
        Back current drain*
        Corresponding to less than 1Ah/month
        Ambient temperature
        -20˚C to +50˚C
        Battery types
        All types of lead-acid batteries, 12V, WET, MF, Ca/Ca, AGM, GEL
        Battery capacity
        40–500Ah
        Warranty
        2 years
        Insulation class
        IP44
        Ripple**
        Less than 4%
        User manual

        MXS_25-safetyinstruction-AU-EN.pdf

        MXS_25-manual-AU-EN.pdf
      • Inside the box
        Product sheet

        MXS_25-Productsheet-low-UK-EN.pdf
        FAQ
        No LED’s are lit on the top row when the charger is connected to both the power outlet and the battery   ×
        The LED’s on the bottom row are lit and you can change charging mode. None of the LED’s in the top row, indicating charging status, are lit.

        Explanation: The battery voltage could be under 2 +/- 0.5V.
        Test: Try to charge the battery in Supply mode for approximately 5 min. Then try regular charging.
        Test: Test the charger on a fresh battery.
        Temperature LED is flashing   ×
        Explanation: The temperature is above + 65 °C. The charging is interrupted. Press the MODE button to restart charging when the temperature has dropped below + 65 °C.
        The error LED is lit   ×
        Explanation 1: Reverse polarity.
        Test: Make sure that the + cable/clamp is connected to the + terminal and the – cable/clamp is connected to the – terminal.

        Explanation 2: Loads are connected to the battery which requires more power than the charger can provide.
        Test: Turn off or disconnect the loads when charging.

        Explanation 3: The clamps are short circuited in Supply mode.
        Test: Separate the clamps.
        No LED is lit when the charger is connected only to the power outlet   ×
        Explanation: One of the LED’s at the lower row should light up when the charger is connected to the power outlet.
        Test: Make sure that there is power from the power outlet.
        Temperature LED is lit   ×
        Explanation Multi XS 25000: DC interruption or short circuit in the cable.

        Explanation MXS 25: This is normal, the LED is on indicating that the temperature sensor is activated. If the LED is turned off here is a DC interruption or short circuit in the cable.
        Temperature LED is lit   ×
        This is normal, the LED is on indicating that the temperature sensor is activated.
        The charger has gone into maintenance mode but cannot see that the recond is completed?   ×
        The Recond program starts with the normal charging program but has a recondition phase inserted after the charging, automatically followed by the maintenance mode. The Recond light “R” on the upper row may be tricky to see, as it will be lit after the third charging lamp, and turns off after the recondition is done, (lasts 0,5h – 4h) and after that the 4th, green maintenance light will be lit.
        is flashing, then turns into error mode   ×
        Explanation: The battery is probably too sulphated to revive. The battery is faulty and it is time to change it.
        is lit and then turns into error mode   ×
        The analysis phase is testing if the battery can retain the charger given.

        Explanation 1: Large loads are connected to the battery and are draining the voltage.
        Test: Disconnect the battery and try charging again.

        Explanation 2: The battery cannot retain the charge given.
        Test: The battery needs replacing.
        No LED is lit when the charger is connected only to the battery   ×
        Explanation: The plug has to be connected for the LED to be lit.