MXS 5.0

Advanced charging with temperature compensation

MXS 5.0

Advanced charging with temperature compensation

MXS 5.0

Advanced charging with temperature compensation
Image missing

Product information

  • Product information

    Advanced charging with temperature compensation

    Cold weather performance

    The MXS 5.0 comes with automatic temperature compensation for the best charging performance, even in extreme conditions.

    The MXS 5.0 is an advanced microprocessor controlled battery charger which gives unrivalled performance for lead acid batteries from 1.2-110Ah. It comes with automatic temperature compensation built in which ensures the best charging performance, even in the most extreme conditions. The MXS 5.0 also includes battery diagnosis to establish whether your battery can receive and retain a charge, patented automatic desulphation program, an AGM option which maximises the performance life of most Stop/Start batteries and a special Recond mode for reconditioning deeply discharged batteries. The MXS 5.0 uses CTEK’s patented float/pulse system, which is the most efficient maintenance mode when a battery is connected for long periods.

      ;*;Fully automatic ‘connect and forget’ 8 step 12V charging ;*;Smaller battery, normal battery, AGM and Recond programs ;*;Built in automatic temperature compensation ;*;Patented float/pulse maintenance for batteries up to 160Ah ;*;5-year warranty
      Technical information
      Input
      220–240VAC, 50–60Hz, 0.6A max
      Output
      14.4V/14.7V/15.8V, 5.0A max
      Start voltage
      2.0V
      Back current drain*
      Corresponding to less than 1Ah/month
      Ambient temperature
      -20˚C to +50˚C
      Battery types
      All types of lead-acid batteries, 12V, WET, MF, Ca/Ca, AGM, GEL
      Battery capacity
      1.2–160Ah
      Warranty
      5 years
      Insulation class
      IP65
      Temperature compensation
      Built in charge voltage temperature compensation according to ambient temperature.
      User manual

      MXS_5.0-safetyinstruction-AU-EN.pdf

      MXS_5.0-manual-AU-EN.pdf
    • Inside the box
      CONNECT CLAMP
      CONNECT EYELET M6
      Product sheet

      MXS_5.0-Productsheet-low-AU-EN.pdf
      FAQ
      is flashing   ×
      If no battery or if the battery voltage is too low the led will start to flash to indicate the unit has entered power save mode.
      Test: Test the charger on a fresh battery.
      is lit   ×
      Explanation 1: Reverse polarity.
      Test: Make sure that the + cable/clamp is connected to the + terminal and the – cable/clamp is connected to the – terminal.

      Explanation 2: Loads are connected to the battery which requires more power than the charger can provide.
      Test: Turn off or disconnect the loads when charging.

      Explanation 3: The charger is not connected to a 12V battery.
      Test: Test with a fresh 12V battery.

      Explanation 4: The charge cycle is interrupted in step 1.
      Test: Test to restart the charge cycle, if it still fails in step 1 the battery is sulphated and needs to be replaced.

      Explanation 5: The charge cycle is interrupted in step 4.
      Test: Test to restart the charge cycle, if it still fails in step 4 the battery is can’t be charged and needs to be replaced.